Tipo | Conductor Ø mm | Dieléctrico Ø mm | Blindaje | Cubierta Ø mm | Impedancia ohms | Capacidad pF/m | Nom. vel. Prop. % | Tens. max. Kv | Nom. aten. dB/100 m Mhz. dB | Bobinas Rollos |
---|---|---|---|---|---|---|---|---|---|---|
RG-59/U | Cu 0,60 |
PE 3,70 |
Cu 94 % 16/7/.15 |
PVC 5,90 |
75 | 67 | 66 | 2,3 | 100 12 200 16,7 400 24 |
R 100 m B 300 m |
RG-59/U 2X | Cu 0,60 |
PE 3,70 |
Cu 1 x 88% 1 x 94% |
PVC 6,30 |
75 | 67 | 66 | 2,3 | 100 12 200 16,7 400 24 |
R 100 m B 300 m |
59-CCTV | Cu/Cw 0,76 |
PE Foam 3,7 |
Foil/Al + Al 16/3/.16 100% |
PVC 5,90 |
75 | 55 | 78 | 0,63 | 100 7,9 200 12 400 16,7 |
R 100 m B 300 m |
6-CCTV | Cu/Cw 1,02 |
PE Foam 4,55 |
Foil/Al + Al 16/4/.16 100 % |
PVC 7,00 |
75 | 54 | 78 | 0,70 | 100
7 200 10 400 16 |
R 100 m B 300 m |
11-CCTV | Cu 1,50 |
Semi Solid. PE Foam 7,25 |
Foil/Al + Al 16/6/.16 100 % |
PVC/PE 10,30 |
75 | 54 | 78 | 0,90 | 100 4,4 200 6,5 400 10 |
R 100 m B 500 m B 900 m |
RG-11/U | CuE 1 x 1,20 |
PE 7,25 |
Cu 16/10/0,18 95 % |
PVC 10,30 |
75 | 67 | 66 | 5 | 100
7 200 10 400 14 |
R 100 m B 300 m |
2YCY | CW 0,40 |
PE 2,52 |
CuE 98 % 16/8/.10 |
PVC 4,00 Gris |
75 | 67,5 | 66 | 2 | 1
2,6 10 5,1 100 18 |
R 100 m B 500 m B 1000 m |
2YCCY | CW 0,40 |
PE 2,52 |
CuE/P 98 % 16/8/.10 |
PVC 4,00 Gris |
75 | 67,5 | 66 | 2 | 1 2,6 10 5,1 100 18 |
R 100 m B 500 m B 1000 m |
2,5C-2V | Cu 0,40 |
PE 2,4 |
Cu 98 % 16/8/.10 |
PVC 4,00 Azul |
75 | 69 | 66 | 2 | 1 1,7 10 5,2 100 17 |
R 100 m B 500 m B 1000 m |
2,5C-2W | Cu 0,40 |
PE 2,5 |
Cu 98 % 16/8/.10 |
PVC 4,70 Azul/Blanco |
75 | 69 | 66 | 2 | 1
1,7 10 5,2 100 17 |
R 100 m B 500 m B 1000 m |
3C-2V | Cu 0,50 |
PE 3,1 |
Cu 98 % 16/7/.15 |
PVC 5,40 Negro |
75 | 67 | 66 | 2 | 1
1,3 10 4,2 100 14 |
R 100 m B 500 m B 1000 m |
3C-2W | Cu 0,50 |
PE 3,1 |
Cu 98 % 2X 16/7/.15 |
PVC 6,5 Negro/Amarillo |
75 | 67 | 66 | 2 | 1
1,3 10 4,2 100 14 |
R 100 m B 500 m B 1000 m |